Compressor Application Manual
9
When choosing the replacement model,
it is very important to check the class of
the original compressor. As you know,
the compressor's operating conditions
can vary according to each design.
In this way, some drinking fountains may
need an HBP while others use an LBP or
MBP compressor.
1.3 - Type of refrigerant fluid
Embraco markets compressors for use
with R 12 and/or blends, R 134a and
R 600a refrigerant fluids.
These compressors differ from each
other inside (motor, pump, oil type,
displacement, etc.) in order to provide
the best performance and guarantee a
highly reliable product.
Classification
Evaporation
Temperature
Example of
Application
LBP
L/MBP
HBP
-35
o
C to -10
o
C
(-31
o
F to +14
o
F)
-35
o
C to -5
o
C
(-31
o
F to +23
o
F)
-5
o
C to +15
o
C
(+27
o
F to +59
o
F)
Freezers
& Refrigerators
Refrigerated food
counters and drinking
fountains
Dehumidifiers, soft drink
machines and drinking
fountains
III
Depending on what kind of compressor
model is involved, it may be used in a
range from the LBP to HBP classification
(see following table).