R and V Works FF6 Información técnica Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
Compressor Application Manual
16
2.2 - Wrong connection at the terminal board
Check the connections using the
refrigerator's electrical diagram.
2.3 - Wiring or electrical components touching
metal parts
Check if there is a fault in the insulation of
an electrical component that is touching
metal parts. Correct the defect.
2.4 - Electrical components interrupting the
current flow to the compressor
Defect in such components as thermostat,
auxiliary transformer, timer, etc. Check.
2.5 - Internal light does not switch off
Check if the light switch has a problem,
such as a poor contact, incorrectly
installed, etc.
2.6 - Inadequate transformer
Check if the transformer is the one specified
in the table in Chapter VI, item 4.
3 - Inadequate Grounding
3.1 - Electrical discharge
Check the ground connection.
If necessary, redo the grounding.
IV