Compressor Application Manual
75
– It requires all components of the system to be
free from contamination (alkaline substances,
grease, wax, water, paraffin, silicone,
chlorinated residues, etc.), due to the
characteristics of the compressor to be used.
To date, there is no definition of a sufficiently
effective cleaning method that is reliable and
reasonably uncomplicated and which
guarantees the simple substitution of the R 12 of
a domestic refrigeration system with R 134a.
R 134a may only be used in compressors
specially designed for its use due to the slightly
higher operating pressures in relation to the
applications with R 12.
These characteristics required a new electric
motor design and chemically compatible
materials employed in its manufacture.
Compressors produced to use R 12, however,
have materials used in their manufacturing
process that are not compatible with the ester
oil used in the same R 134a.
Due to problems of chemical compatibility,
it will be necessary to use a special filter drier for
the R 134a.
Due to the high hygroscopicity of the ester
oil used in the compressors specifically for
R 134a, we recommend that the compressor or
system does not remain open to the air for more
than 15 minutes. The vacuum process using a
pump is mandatory.