Compressor Application Manual
15
IV
1 - Problems and Solutions
1.1 - Voltage
1.1.1 - No voltage at power supply
Check using a voltmeter or test
lamp.
1.1.2 - Very low voltage at power supply
To eliminate problems of voltages
below 103 V (115 V nominal) and
198 V (220 V nominal), at the end
of the Manual we recommend the
use of a voltage stabilizer.
When the compressor does not
start, the problem can be solved
most often by using the right
starting capacitor.
1.1.3 - Very high voltage
To eliminate the problem of
voltages above 132 V (115 V
nominal) and 240 V (220 V
nominal) we recommend the use
of a voltage stabilizer.
2 - Electrical Parts
2.1 - Interrupted electric cable or wiring
Using a test lamp or ohmmeter, check if
the cable or wiring is not interrupted. Also
check the plug.