Compressor Application Manual
25
8.3 - Capillary blockage due to water /
wax / paraffin
Check if ice has formed at the entrance
to the evaporator. Warm this point and
check if the refrigerant fluid starts
circulating. If so, it is a sign that there is
water in the system. In this case, you
must remove the water from the circuit
replace the filter drier and put in a new
refrigerant fluid charge.
(See the necessary procedures for
changing the hermetic compressor from
page 34 onwards in this Manual).
IV
Figure 21 - Probable sources of noise in refrigerators
Stability of
refrigerator
structure
Refrigerant
flow
Size of process tube
(must be quite short)
Blades out of balance
and the volume of air
drawn in by the fan in
forced ventilation systems
Fastening of
condenser
Tubing
(Must be with
bends)
Refrigerator
fastening bar
Refrigerator base Compressor fastening
Vista de pagina 26