Compressor Application Manual
50
2 - Filter Driers
There are filter driers suitable for each refrigerant
fluid. See the following table:
3 - Start Capacitor
EMBRACO compressors with an LST motor were
designed to work without a start capacitor, under
normal conditions of use.
However, when there are problems with the
electricity distribution grid or unequal pressures at
the start up, a starting capacitor can solve the
problem. Use the specified starting capacitor,
according to the following table.
The installation of a capacitor outside the
specifications may worsen the start up.
Note: If the compressor is not working because
there is no starting capacitor, changing it for
the incorrect compressor may cause further
damage. The operation of the thermal
protector can be blocked or delayed to the
extent of causing the compressor to burn out.
The least damage would be serious damage
to the working life of the compressor.
3.1 - FF BX and FF HBX compressors
For FF BX, FFHBX or other compressors
with the letter "X" in their name, the
starting capacitor must be used, as
shown in the following tables:
Refrigerant
Recommended Filter Drier
XH5, XH6, Universal (MS594)
XH7, XH9, Universal (MS594)
XH5, XH6, Universal (MS594)
XH9, Universal (MS594)
R 12
R 134a
R 600a
Blends